American Microwave Corporation
7309-A Grove Road
Frederick, MD 21704

Phone:301-662-4700
Fax:301-662-4938
sales@americanmic.com
 

ISO -9001:2015

In Pursuit of Excellence
Through Engineering since 1978

SWN-2181-TRA2/3-IND-SP

Transfer Switch With Independent Control
and Solder Pins

Specifications:


Frequency Range
0.5 – 18 GHz

Insertion Loss
3.5 dB Maximum @ 18 GHz

Isolation
40 dB Minimum (TRA2)

65 dB Minimum (TRA3)


VSWR
In/Out: 2.0:1

Speed
Rise: 10 ns Typical, 15 ns Maximum

Fall: 10 ns Typical, 15 ns Maximum

Delay On: 75 ns Typical, 100 ns Maximum

Delay Off: 75 ns Typical, 100 ns Maximum


Power Supply
+5V @ 150 mA Maximum

– 5V @ 150 mA Maximum


Power Input
(CW) +20 dBm (Standard), +10 dBm (High Speed)

Survival Power
1 Watt CW, 10 Watts Peak 1 usec

Size
1.00″(L) X 1.00″(W) X 0.75″(H)

Weight
1.5 Oz Maximum

Available Options:

 Independent Control With
Solder Pin Standard

 IND-SP Independent Control with Solder Pin
 SMC SMC Control (Male)
 IND-SMC Independent Control with SMC Control (Male)

10M18
10 MHz to 18 GHz (Insertion Loss Increases

by 1.5 dB at 10 MHz and 0.5 dB at 18 GHz)


100M18
100 MHz to 18 GHz (Insertion Loss Increases

by 1.5 dB at 100 MHz and 0.5 dB at 18 GHz)


118
1 – 18 GHz (No Change in Insertion Loss)

218
2 – 18 GHz (No Change in Insertion Loss)

412
4 – 12.4 GHz (No Change in Insertion Loss)

618
6 – 18 GHz (No Change in Insertion Loss)

1218
12 – 18 GHz (No Change in Insertion Loss)

100M20
100 MHz – 20 GHz (Insertion Loss Increases by

1.5 dB at 100 MHz and 1.0 dB at 20 GHz)


220
2 – 20 GHz (Insertion Loss Increases by 1.0 dB
at 20 GHz)

1020
10 – 20 GHz (Insertion Loss Increases by

1.0 dB at 20 GHz)


B01
-12V Power Supplies

B02
-15V Power Supplies

B03
Reverse Logic

B05
High Speed, Turnon/Turnoff 20 nsec Maximum
when Applicable or Option HS

B06
High Power – Specify CW Power, Peak Power,
Pulse Width, Duty Cycle,

RF Frequency and Bandwidth


B07
Custom Designed Product – Specify Initials of Customer

B08
Low Video Transients – Specify Video Bandwidth

B09
Low Insertion Loss Version

B10
Higher Isolation Version

Environmental Ratings:

Our standard
environmental ratings are as follows, for specific
requirements please contact us…

Temperature:
 -55 ºC to +85
ºC Operating
 -65
ºC to +125 ºC Non-Operating
 Humidity:  MIL-STD-202F,
Method 103B Cond. B
 Shock:  MIL-STD-202F,
Method 213B Cond. B
 Vibration:  MIL-STD-202F,
Method 204D Cond. B
 Altitude:  MIL-STD-202F,
Method 105C Cond. B

Temperature Cycle:
 MIL-STD-202F,
Method 107D Cond. A

Outline Drawing:

Click here to see the Outline Drawing for
SWN-2181-TRA2/3-IND-SP

Product Feature:

Click here to see the Product Feature for
SWN-2181-TRA2/3-IND-SP