SWN-2181-TRA Option AL1W

AMC Model SWN-2181-TRA Option AL1W is a Transfer
Switch Module With

Low Insertion Loss,
High Isolation, and Integral TTL Driver in a Small 1.0″ x 1.0″
x 0.5″

Package,
Designed for 0.5 GHz to 18 GHz Operation.

Specifications:


Frequency Range
0.5 – 18 GHz

Insertion Loss
3.5 dB Maximum @ 18 GHz

Isolation
60 dB Minimum

VSWR
In/Out: 2.0:1

Speed
Delay On: 75 ns Typical, 100 ns Maximum

Delay Off: 75 ns Typical, 100 ns Maximum


Operating Power Input
+30 dBm (1 Watt) 75 W Peak (1 usec Pulse Width)

Survival Power
+33 dBm 100 W Peak (1 usec Pulse Width)

Power Supply
+5V @ 100 mA Maximum

– 5V @ 100 mA Maximum


Size
1.00″(L) X 1.00″(W) X 0.50″(H)

Weight
1.5 Ounces Typical

Available Options:

 

 Single
Control With Solder Pin Standard

 IND-SP Independent Control With Solder Pin

10M18
10 MHz to 18 GHz (Insertion Loss Increases

by 1.5 dB at 10 MHz and 0.5 dB at 18 GHz)


100M18
100 MHz to 18 GHz (Insertion Loss Increases

by 1.5 dB at 100 MHz and 0.5 dB at 18 GHz)


118
1 – 18 GHz (No Change in Insertion Loss)

218
2 – 18 GHz (No Change in Insertion Loss)

412
4 – 12.4 GHz (No Change in Insertion Loss)

618
6 – 18 GHz (No Change in Insertion Loss)

1218
12 – 18 GHz (No Change in Insertion Loss)

100M20
100 MHz – 20 GHz (Insertion Loss Increases by

1.5 dB at 100 MHz and 1.0 dB at 20 GHz)


220
2 – 20 GHz (Insertion Loss Increases by 1.0 dB
at 20 GHz)

1020
10 – 20 GHz (Insertion Loss Increases by

1.0 dB at 20 GHz)


B01
-12V Power Supplies

B02
-15V Power Supplies

B03
Reverse Logic

B05
High Speed, Turnon/Turnoff 20 nsec Maximum
when Applicable or Option HS

B06
High Power – Specify CW Power, Peak Power,
Pulse Width, Duty Cycle, RF Frequency and Bandwidth

B07
Custom Designed Product – Specify Initials of Customer

B08
Low Video Transients – Specify Video Bandwidth

B09
Low Insertion Loss Version

B10
Higher Isolation Version

Environmental Ratings:

Our standard
environmental ratings are as follows, for specific
requirements please contact us…

Temperature:
 -55 ºC to +85
ºC Operating
 -65
ºC to +125 ºC Non-Operating
 Humidity:  MIL-STD-202F,
Method 103B Cond. B
 Shock:  MIL-STD-202F,
Method 213B Cond. B
 Vibration:  MIL-STD-202F,
Method 204D Cond. B
 Altitude:  MIL-STD-202F,
Method 105C Cond. B

Temperature Cycle:
 MIL-STD-202F,
Method 107D Cond. A

Outline Drawing:

Click here to see the Outline Drawing for 

SWN-2181-TRA Option AL1W

Product Feature:

Click here to see the Product Feature for 



SWN-2181-TRA
Option AL1W

Test Data:

Click here to see Test Data on

SWN-2181-TRA Option AL1W