LVD-618-50

 
The LVD-618 Series DLVA’s are Available
in Standard 50 dB and Extended 70/75 dB
Dynamic Range Over the 6-18 GHz Bandwidth, With True DC
Coupling.  Units Employ
Planar Diode Detectors and Integrated Video Circuitry for High
Speed Performance and
Outstanding Reliability.  The DLVA’s are of Superior
Construction Using State-of-the-Art
MIC/MMIC Technology.

Specifications:


 Frequency Range

6 – 18 GHz


 Frequency Flatness

±1.5 dB Maximum


 Logging Range

-40 to -0 dBm Minimum


 Useful Range

-40 to +5 dBm


 Log Linearity Error

±1.0 dB Maximum (-40 to 0 dBm)


 Log Slope

50 mV/dB


 Log Sloe Accuracy

±10% of Average Slope


 Temperature Stability

±1.0 dB Maximum (-54º
to +85ºC)


 Pulse Response

50 nS to CW


 Rise Time

15 nS Maximum


 Settling Time

45 nS Maximum


 Recovery Time

250 nS Typical, 500 nS Maximum


 TSS

-40 dBm Minimum


 VSWR (RF)

2.5 Maximum


 Maximum RF Input

+15 dBm


 Video Output Level

0 to 2.5 Volts (50 Ohm Minimum Load)


 DC Power (No Load)

+V: 9 to 18V @ 120 mA Maximum
– V: 9 to 18V @   80 mA Maximum


 Size

2.2″ X 1.5″ X 0.4″


 Video Load

50 Ohms Minimum

 

Available Options:
 

 A01

Extended 0.2 to 20 GHz RF Frequency Range


 A02

Extended 0.5 to 18 GHz RF Frequency Range


 A04

Alternate Log Slopes


 A05

High Power RF CW/Peak Protection


 A06

Extended Logging Range (-67 dBm to
+10 dBm)


 A07

Other Video Loads


 A08

Recovery Time, 250 nS Maximum


 A09

Frequency Flatness of +1 dB Maximum

Environmental Ratings:

Our standard
environmental ratings are as follows, for specific
requirements please contact us…

 Temperature:
 -54 ºC to +85
ºC Operating
 -65
ºC to +100 ºC Non-Operating
 Humidity:  MIL-STD-202F,
Method 103B Cond. B
 Shock:  MIL-STD-202F,
Method 213B Cond. B
 Vibration:  MIL-STD-202F,
Method 204D Cond. B
 Altitude:  MIL-STD-202F,
Method 105C Cond. B

 Temperature Cycle:
 MIL-STD-202F,
Method 107D Cond. A

 

Outline Drawing:

Click here to see the Outline Drawing for
LVD-618-50

 

Product Feature:

Click here to see the Product Feature for
LVD-618-50

 

Test Data (10/31/04):

Click here to see Test Data on

LVD-618-50

 

More Test Data (11/22/04):

Click here to see More Test Data on

LVD-618-50

 

More Test Data (12/20/04):

Click here to see More Test Data on

LVD-618-50

 

More Test Data (04/27/05):

Click here to see More Test Data on

LVD-618-50

 

Test Data (11/06/07):
Click here to see More Test Data on

LVD-618-50