American Microwave Corporation
7309-A Grove Road
Frederick, MD 21704

Phone:301-662-4700
Fax:301-662-4938
sales@americanmic.com
 

ISO -9001:2015

In Pursuit of Excellence
Through Engineering since 1978

LVD-218-70 OPTION 120, 100MV

 
AMC Model LVD-218-70 Option 120, 100MV
is available with -65 dBm to -25 dBm
Dynamic Range over the full 1 to 20 GHz Bandwidth, with true
DC Coupling.  Units
Employ Planar Diode Detectors and Integrated Video Circuitry
for High Speed
Performance and Outstanding Reliability.  The DLVA’s
are of Superior Construction
using State-of-the-art MIC/MMIC Technology.  The size
is 3.0″ x 3.5″ x 0.5″.

Specifications:


 Frequency Range

1 to 20 GHz


 Frequency Flatness

±1.75 dB (±1.5
dB 6-18 GHz)


 TSS

-68 dBm (-70 dBm 6-18 GHz)


 VSWR

2.5:1


 Dynamic Range

-65 dBm Minimum (-68 dBm Typical) to -25 dBm Typical


 Logging Range

-65 dBm to +10 dBm


 Log Linearity

±1.75 dB (±1.5
dB 6-18 GHz)


 Log Slope

100 mV/dB or as desired


 Log Slope Accuracy

±5% Maximum of Average
Slope


 Log Temperature Stability

±1.75 dB (±1.50
dB 6-18 GHz)


 Rise Time

30 ns Maximum, 20 ns Typical


 Recovery Time

200 ns Typical, 300 ns Maximum


 Video Load

50 Ohms (Typical), or as desired


 DC Power (No Load)

 
   +V 9 to 18V @ 350 mA
   -V 9 to 18V @ 200 mA Maximum


 Size

3.00″ x 3.50″ x 0.50″

 

Available Options:
 


 A01

Extended 0.2 to 20 GHz RF Frequency Range


 A02

Extended 0.5 to 18 GHz RF Frequency Range


 A03

Faster Rise/Recovery Times


 A04

Alternate Log Slopes


 A05

High Power RF CW/Peak Protection


 A06

Extended Logging Range


 A07

Other Video Loads

Environmental Ratings:

Our standard
environmental ratings are as follows, for specific
requirements please contact us…

 Temperature:
 -54 ºC to +85
ºC Operating
 -65
ºC to +100 ºC Storage
 Humidity:  MIL-STD-202F,
Method 103B Cond. B
 Shock:  MIL-STD-202F,
Method 213B Cond. B
 Vibration:  MIL-STD-202F,
Method 204D Cond. B
 Altitude:  MIL-STD-202F,
Method 105C Cond. B

 Temperature Cycle:
 MIL-STD-202F,
Method 107D Cond. A

 

Outline Drawing:

Click here to see the Outline Drawing for
LVD-218-70 OPTION 120, 100MV

 

Product Feature:

Click here to see the Product Feature for
LVD-218-70 OPTION 120, 100MV