American Microwave Corporation
7309-A Grove Road
Frederick, MD 21704

Phone:301-662-4700
Fax:301-662-4938
sales@americanmic.com
 

ISO -9001:2015

In Pursuit of Excellence
Through Engineering since 1978

DVA-50

 
AMC Model DVA-50 Provides a Linear
Amplified Video Output Voltage Proportional
to the Input RF Voltage, Where the Video Output = K x VIN. 
(A Typical Value for
K is 6, For a Video Output Between 0 and 5 Volts.)  This
Unit Operates From 6
to 18 GHz with Typical Transfer Law Linearity of ±0.5 dB
Between Input Power
Levels of -5 and +15 dBm.  Frequency Flatness Over the 6
to 18 GHz Range is
±1.5 dB With a Signal to Noise Ratio Greater Than 60 dB at -5
dBm Input Power.
Input VSWR is Better Than 2.0:1.  Current Draw is Under
30 mA Per Supply Between
±9 and ±18 Volts.  Size is 2.2″ x 1.5″ x 0.4″.

Specifications:


 Frequency Range

6 – 18 GHz


 Frequency Flatness

±1.5 dB Maximum


 VSWR (RF)

2:1 Maximum


 Input Power Range

-5 to +15 dBm


 Maximum Input Power

+20 dBm


 Video Output

0 to 5 Volts Maximum


 Video Load

50 Ohm Minimum


 Signal to Noise Ratio

60 dB Minimum @ -5 dBm Input


 Output Linearity

±0.5 dB Typical, ±0.7 Maximum


 Rise Time

20 nS Maximum


 Fall Time

50 nS Maximum


 Baseline Stability

±10 mV


 Output Stability

±0.75 dB Maximum (0 to 60ºC)


 DC Power (No Video Load)

+V: +9 to 18 Volts @ 30 mA Maximum
– V: – 9 to 18 Volts @ 30 mA Maximum


 Connectors

RF Input/Video Output: SMA (Female)
Power Supply: Solder Pin


 Size

2.2″ X 1.5″ X 0.4″

 

Available Options:
 

 A01

Extended Frequency Range (0.5 to 18 GHz)


 A02

-54º
to +85
º Operating
Temperature


 A03

Alternate Video Transfer Gain


 A04

Other Rise/Fall Times

Environmental Ratings:

Our standard
environmental ratings are as follows, for specific
requirements please contact us…

 Temperature:
 0 ºC to +60
ºC Operating
 -65
ºC to +100 ºC Non-Operating
 Humidity:  MIL-STD-202F,
Method 103B Cond. B
 Shock:  MIL-STD-202F,
Method 213B Cond. B
 Vibration:  MIL-STD-202F,
Method 204D Cond. B
 Altitude:  MIL-STD-202F,
Method 105C Cond. B

 Temperature Cycle:
 MIL-STD-202F,
Method 107D Cond. A

 

Outline Drawing:

Click here to see the Outline Drawing for
DVA-50

 

Product Feature:

Click here to see the Product Feature for
DVA-50

 

Test Report:
Click here to see the Test Report for
DVA-50